We provide individual EV assays and coordinated projects that extend from isolation and characterization to molecular cargo analysis. The service scope is matched to the sample, comparison design, and results required.
We process conditioned media, biofluids, tissue-derived material, and other research samples using concentration, size-based separation, density separation, or affinity capture. A small-EV-focused exosome isolation and purification service is available when the project specifically targets that population.
Our core characterization options include nanoparticle tracking analysis for particle size and concentration and transmission electron microscopy for representative vesicle morphology. The tests may be ordered separately or combined with marker analysis.
Protein-marker assays help evaluate EV enrichment and likely co-isolated material. For studies that need marker-positive particle counts or marker colocalization, ExoView EV profiling provides immunocapture-based single-particle analysis. Before confirming a marker panel, we review species reactivity, sample source, expected target abundance, and validated antibody availability.
Characterized EV preparations can be analyzed by extracellular vesicle proteomics, extracellular vesicle metabolomics, or exosome lipidomics. Before processing, we plan aliquot allocation and quality controls so characterization and omics data remain linked to the same EV preparation and biological comparison.
We select the starting assay according to the submitted material and the evidence required for preparation quality, group comparison, subpopulation analysis, or cargo discovery.
Begin with particle size and concentration, representative microscopy, and EV-associated plus source-appropriate non-EV markers. This combination provides a more complete quality picture than any single measurement alone.
Use consistent sample collection and isolation across all groups, then compare particle measurements, selected markers, or single-particle phenotypes. ExoView or another targeted platform is most useful when the study centers on defined surface markers or EV subpopulations.
Combine EV enrichment and basic characterization with the appropriate proteomic, metabolomic, or lipidomic workflow. Process blanks and relevant biological controls help separate EV-associated changes from media, biofluid, or isolation-related background.
For exosome-focused characterization, engineered exosome studies, or small-EV subpopulation analysis, see our exosome analysis services. We use “extracellular vesicle” or “small EV” when the available data do not establish a specific biogenesis pathway.
Figure 1. EV analysis can be scoped for preparation quality, group comparison, marker-defined subpopulations, or molecular cargo discovery.
Isolation affects EV recovery, sample purity, and compatibility with later assays. We select a method or method combination around the sample matrix and the planned analysis.
| Method | Recommended For | Project Considerations |
|---|---|---|
| Differential ultracentrifugation | Broad EV enrichment from conditioned media or biofluids | Can co-pellet proteins, lipoproteins, and aggregates; rotor, force, time, and wash conditions affect recovery |
| Size-exclusion chromatography | Gentle separation of EV-sized particles from many smaller soluble components | Fractions may be dilute, and similarly sized lipoproteins or nanoparticles can remain |
| Density-gradient separation | Projects that need additional separation from particles with different buoyant densities | Often trades recovery and processing capacity for improved separation |
| Ultrafiltration or tangential-flow filtration | Concentrating larger volumes of conditioned medium before a polishing step | Filter selection, membrane retention, and co-concentration of soluble material require attention |
| Polymer precipitation | Rapid enrichment when broad recovery is more important than analytical purity | Co-precipitated proteins and polymer carryover can suppress mass-spectrometry signals; cleanup may be necessary |
| Immunoaffinity enrichment | Enrichment of EVs carrying a selected surface marker | The antibody defines which particles are captured and excludes marker-negative populations |
Planning downstream omics? Tell us before isolation begins. A preparation that is adequate for particle counting may still contain proteins, lipoproteins, salts, or polymers that interfere with proteomic, metabolomic, or lipidomic analysis.
Each technique answers a different question. We combine size, morphology, and molecular measurements when a study needs a fuller assessment of an EV preparation.
| Technique | Measurement | Recommended For |
|---|---|---|
| Nanoparticle tracking analysis | Particle-size distribution and concentration based on light scattering | Recovery checks, dilution assessment, and comparisons across samples or groups |
| TEM or cryo-electron microscopy | Representative particle morphology, membrane-delimited structures, aggregates, and debris | Visual assessment of an EV preparation alongside quantitative and marker data |
| Western blot or immunoassay | EV-associated proteins and selected non-EV or source-related components | Evaluating enrichment and likely co-isolated material |
| Flow or nano-flow cytometry | Scatter and fluorescence signals from detectable individual particles | Targeted comparison of labeled EV populations |
| SP-IRIS / ExoView | Immunocaptured particle counts, surface-marker phenotype, and fluorescence colocalization | Marker-defined EV subpopulations and targeted phenotype studies |
| Zeta potential | Surface-charge behavior under specified buffer conditions | Comparing colloidal behavior across formulations or storage conditions |
NTA counts light-scattering particles, microscopy examines selected fields, and a marker assay measures the combined signal from the submitted preparation. Results are interpreted together rather than using one test as stand-alone proof of EV identity or purity.
Our characterization plans are informed by MISEV2023 recommendations. Depending on the sample source and research question, we combine quantitative, imaging, and molecular measurements and evaluate both EV-associated and source-relevant non-EV components. CD9, CD63, and CD81 may be included in marker panels, but no single tetraspanin is treated as universal or exosome-specific.
We accept source samples and pre-isolated EVs. The ranges below are practical starting points, not fixed minimums; the final amount depends on the assay combination, replicate plan, and expected EV abundance.
| Starting Material | General Starting Amount | What We Need to Know |
|---|---|---|
| Cell-culture-conditioned medium | Typically 50–100 mL or more per biological sample for integrated isolation and multi-omics | Cell number or confluence, viability, conditioning time, medium, supplements, and EV-depletion procedure |
| Plasma or serum | Typically 1–3 mL per biological sample; deeper omics or repeat testing may require more | Collection tube, anticoagulant, processing delay, platelet removal, hemolysis, storage, and freeze-thaw history |
| Urine | Typically 30–50 mL per biological sample, depending on concentration and study design | Collection timing, clarification, preservatives, storage, and any planned concentration or normalization |
| Other biofluids or tissue-derived material | Assessed case by case | Collection method, available volume or mass, expected contaminants, and planned downstream tests |
| Pre-isolated EVs | For multi-omics, approximately 109–1010 particles or 10–20 μg EV-associated protein is a useful planning target; selected characterization tests may require less | Source, isolation method, buffer, final volume, particle and protein measurements, marker results, and storage conditions |
If sample is scarce, we can begin with the measurement most important to the study and reserve optional testing for a pilot or follow-up phase. Please contact us before collecting a full cohort so that sample volume, controls, and storage can be planned together.
For plasma projects, use one anticoagulant and one processing protocol consistently across all study groups. Contact us before collection because EDTA, citrate, and heparin can differ in downstream assay compatibility.
Aliquot samples to reduce repeated freeze-thaw cycles, store them at −80°C when appropriate, and ship on dry ice unless we provide different instructions for the selected matrix or assay.
Figure 2. A typical EV project progresses from sample and study review through isolation, characterization, optional cargo analysis, and reporting.
We confirm the sample type, comparison groups, available amount, isolation status, requested assays, and intended use of the results.
Collection records, clarification, storage, and freeze-thaw history are reviewed, and source samples are prepared consistently across the study.
We isolate EVs using the agreed method or assess submitted EV material for buffer, concentration, preparation history, and assay compatibility.
Size, concentration, morphology, markers, surface charge, or single-particle phenotype are measured according to the study goal.
Protein, metabolite, or lipid analysis is performed when included, with preparation and controls selected for the analyte class and available input.
We review analytical quality, comparisons, and assay-specific limitations, then provide the agreed figures, result tables, data files, and scientific summary.
Deliverables depend on the services selected. Each report identifies the sample preparation and assay conditions needed to interpret the data.
Each comparative project uses a fit-for-purpose quality plan. Depending on the sample and assay, this may include process blanks, matched collection and processing, pooled quality-control samples, technical controls, and review of biological-replicate consistency. Candidate markers and pathways are presented as research findings for follow-up, not as validated diagnostic conclusions.
EV analysis can support a range of research questions without forcing every project into the same testing package.
For research-stage engineered EV projects, we can compare particle recovery, size distribution, surface-marker profiles, cargo-associated signals, and consistency across constructs or preparation conditions. Quantitative loading-efficiency or surface-integrity testing is defined separately when suitable assays and reference materials are available.
We plan aliquots before processing so particle, marker, and molecular-cargo results can be interpreted within the same biological comparison.
Isolation and cleanup are selected with the next assay in mind, reducing avoidable protein, lipoprotein, salt, or polymer interference in mass-spectrometry workflows.
Particle measurements, images, EV-associated markers, and source-relevant non-EV components are reviewed together rather than treating one measurement as proof of identity or purity.
For scarce samples, we protect the primary endpoint first and confirm whether the remaining material can support phenotype or multi-omics analysis.
Share your sample type, study groups, available amount, isolation status, and whether you need characterization, phenotype analysis, or multi-omics. We will recommend a focused service plan and suitable starting material.
Can I order a single EV test rather than a complete package?
Yes. NTA, microscopy, marker analysis, single-particle profiling, and selected molecular tests may be scoped individually when the sample and question are suitable. We can also combine them into one project when you need isolation, characterization, and cargo analysis from the same study.
Can Creative Proteomics start from source samples rather than purified EVs?
Yes. Projects may begin with conditioned medium, plasma, serum, urine, another biofluid, tissue-derived material, or a submitted EV preparation. We review the source, available amount, collection and storage history, and requested tests before confirming sample instructions.
What is the minimum sample amount for EV analysis?
There is no universal minimum because each test consumes a different amount. General planning targets include 50–100 mL conditioned medium, 1–3 mL plasma or serum, 30–50 mL urine, or approximately 109–1010 particles or 10–20 μg EV-associated protein for multi-omics. We confirm the final requirement after reviewing the assay combination and sample properties.
What if I have less sample than the suggested amount?
Send the available volume, concentration, particle count, protein amount, and previous results if known. We may recommend a focused pilot, prioritize one characterization endpoint, or defer optional assays so that limited material is used where it provides the most value.
Which EV tests are appropriate for a publication?
The appropriate set depends on the statement the study needs to support, the sample source, and the isolation method. A common starting combination includes particle size and concentration, representative imaging, and EV-associated plus non-EV markers. Additional phenotype, purity, or cargo analysis may be needed for the specific research question.
Can NTA or TEM alone confirm that my sample contains exosomes?
No. NTA measures light-scattering particles and their size distribution, while TEM provides representative morphology from imaged fields. Neither method alone establishes EV identity, sample purity, or endosomal origin. Interpret them with marker data, the isolation method, and the sample background.
Which EV isolation method is best?
The best method depends on the matrix and the next assay. Size-exclusion chromatography removes many soluble proteins but may retain similarly sized particles. Ultracentrifugation concentrates a broad particle population but may co-pellet contaminants. Immunoaffinity isolates marker-positive particles but does not represent all EVs. Some projects benefit from combining concentration and cleanup steps.
Can characterization and multi-omics be performed in the same project?
Yes, when the available material supports both. We plan sample allocation before processing so that characterization and molecular results remain connected to the same biological comparison. For limited samples, the primary endpoint is protected first.
How many biological replicates should I include?
A single sample can support feasibility or preparation-quality assessment, but group comparisons generally require independent biological replicates. The appropriate number depends on expected biological variability, effect size, sample availability, and the planned analysis. For scarce material, a pilot can be used to assess recovery and variability before committing the full cohort.
Can you assess EVs from different species or uncommon sample types?
Feasibility is reviewed for each source. We consider available volume, expected EV abundance, matrix background, collection conditions, and compatibility with the requested assay. For uncommon biofluids, tissue-derived material, or nonstandard research models, contact us before collection so the preparation and controls can be planned appropriately.
How is an EV marker panel selected?
Marker selection depends on species, sample source, expected EV population, research question, and validated antibody availability. Panels may include EV-associated proteins together with source-relevant non-EV components so enrichment and likely co-isolated material can be evaluated in context.
For Research Use Only. Not for use in diagnostic procedures.